5  Routing

At its core, the Operator has a powerful routing engine that you can use to move MIDI around in any way you like.

5.1 Routing model

5.1.1 Overview

Routes are defined around outputs. Each physical output on the Operator decides which inputs it takes MIDI from. Before emitting anything, an output passes its incoming messages through a series of filters and then through the modes it has loaded. Modes are explained in detail in Chapter 9

Figure 5.1: Output 1 default message flow where only Input 1 is enabled. Every output sets its inputs independently, parallel to each other.

In the diagram above, Output 1 has Input 1 enabled. All incoming messages are first filtered by their type (notes, CC and so on), after which four additional filters refine what reaches the next step.

Every input has its own stack of four filters, each with its own configuration. The four stacks drawn greyed and dashed are the ones Output 1 does not take in this configuration. Any incoming MIDI message that fails the current configuration for a given output is dropped.

5.1.2 Message filtering reference

An arriving message is checked against the following filters in order:

  1. Msg Types asks what kind of message this is. Setting this affects every incoming message regardless of its input.
  2. Channels asks which channel it arrived on. Notes, control changes, program changes, pitch bend and aftertouch carry a channel. Clock, transport, system exclusive and the system messages do not.
  3. Note Range checks whether a note falls inside a specific range.
  4. CC Range checks whether a CC falls inside a specific range.
  5. Ch Remap is not a filter but a message rewrite. Every message that carries a channel leaves on the channel this row names.

A message that fails any of the checks above is dropped from the output.

5.1.3 Clock routing

Filtering clock messages works slightly differently from the rest. All outputs receive clock messages from the input set in the Master Clock setting in the Operator’s main menu, so enabling or disabling the Clock message type affects the incoming clock from the Master Clock instead of whatever inputs are currently selected for an output. More details on how clock is handled can be found in Chapter 6

5.1.4 Merging multiple inputs

After the filters, every message that passes is merged into a single stream. That stream runs through the output’s chain of modes, and what leaves the chain goes out of the physical output. The merge is a plain interleave. Every message that passes an input’s filters is written to the output in the order Operator took it off the wire.

System exclusive is the only exception to message merging. A system exclusive message takes over an output until it ends. Any other input’s system exclusive message is dropped, and everything else waits for the message to end before being routed again.

5.2 Routing settings persistence

Input filter configuration is persisted and not cleared if an output decides to unset any given input. When an output sets that input again, all of its filter settings come back exactly as they were. The Reset row in the Output settings menu is what returns every one of an output’s filters to the factory state at once.

With one input assigned, Channels, Note Range, CC Range and Ch Remap open their editors straight away. With multiple inputs, each of those rows opens a list of the assigned inputs first, to let you set each input separately.

Msg Types is the only exception. There’s no input-selection submenu for it, and a change made there is applied to every input the output currently holds.

5.3 Routing configuration example

We’ll set the routing configuration for the following scenario: a controller, a drum machine and a synth. The controller’s notes should play the synth, its knobs should drive the drum machine, and the drum machine should keep the synth in time.

Figure 5.2: Example scenario where a MIDI controller drives two machines and one of them acts as a clock source

Connect the controller’s MIDI output to Input 1, since everything it sends is routed on from there to both the synth and the drum machine. The drum machine is both played and drives the tempo for the whole setup, so its MIDI output goes to Input 2 and Output 2 comes back to its MIDI input. Output 1 goes to the synth.

Now to configure the routing:

  1. From the home screen, press SELECT to open the main menu. Scroll to Master Clock and Change it to In 2. The drum machine is now the setup’s master clock.
  2. Scroll back to Outputs and Enter it, then Enter Output 1. Enter the Inputs menu and make sure only Input 1 is checked, clearing anything else with Change. Go Back to the Output 1 settings menu.
  3. Scroll to Msg Types and Enter. Press Enter on All/None to clear any selection, then Scroll to Notes and Change to check it, doing the same for Clock. Now the synth receives the controller’s notes and nothing else, plus the clock, which arrives from Input 2 even though Output 1 does not take that input. Go Back twice to get to the Outputs list.
  4. Enter Output 2, then Enter Inputs. Scroll to Input 1 and Change to check it, then Scroll to Input 2 and Change to clear it, so only Input 1 is checked. Now the drum machine receives MIDI from the controller. Go Back to the Output 2 settings menu.
  5. Scroll to Msg Types and Enter. Press Enter on All/None to clear all nine types, then Scroll to CC and Change to check it. Now the drum machine will only receive CC messages from Input 1.
Note

If you are unsure what Scroll, Change, Enter and Back mean, they are set out in Section 4.3.1

The synth now plays what the controller plays, in time with the drum machine. The drum machine takes the controller’s knobs and nothing else, because Output 2 passes only CC data, so the machine generating the clock never receives it back.

5.4 Output menu reference

Routing is set in each output’s configuration screen. Entering Outputs in the main menu presents a list holding every output, and every row there opens the same screen, named for the output it was opened for. The home screen is the quicker way in: turn DATA to highlight an output column, then press DATA.

Figure 5.3: Output 1 configuration screen

If an output is disabled, it shows a Disable toggle and nothing else. Menu items appear and disappear as the configuration changes, always in the order below:

  1. Inputs. Defines which inputs this output receives MIDI from.
  2. Channels. Defines which MIDI channels pass, per input.
  3. Msg Types. Defines the MIDI message types to allow.
  4. Note Range. Passes notes only if they fall inside a specific range.
  5. CC Range. Similar to Note Range, defines a range of allowed CC messages.
  6. Ch Remap. Rewrites the channel of every message that carries one to the channel set here.
  7. Clock Source. Defines an input to receive clock messages from. It only appears when there is no Master Clock set, the output takes more than one input, and Clock is checked in its Msg Types. More details on how clock is handled can be seen in Chapter 6
  8. Modes. The chain of modes this output runs. Chains are covered in Chapter 9 Factory-provided modes are covered in Chapter 10
  9. Disable. Turns off the output completely. A disabled output receives nothing at all, and its configuration screen shows this row alone to switch the output back on.
  10. Reset. Returns this output to its factory state: input assignments, filters for every input, channel remap and clock source.

5.4.1 Output configuration screens reference

Every screen these rows open follows one of the patterns set out in Chapter 4

Inputs, Channels and Msg Types are all multiple selection screens, with All/None always in their first row.

Figure 5.4: Inputs selection screen
Figure 5.5: Channels selection screen
Figure 5.6: Msg Types selection screen

Note Range and CC Range are range selection screens. Full range is the factory default for both, which reads C-1 (0) to G9 (127) for notes and 0 to 127 for CC.

Figure 5.7: Note Range screen
Figure 5.8: CC Range screen

Ch Remap and Clock Source are edited in place rather than in a different screen.

Figure 5.9: Ch Remap setting under an output configuration screen
Figure 5.10: Clock Source setting under an output configuration screen

Disable switches the output off and back on. Reset asks for confirmation before reverting an output to its factory state.

Figure 5.11: Disabled output configuration screen
Figure 5.12: Reset confirmation alert