8  MIDI Monitor

The MIDI Monitor lets you inspect the MIDI streams passing through the device in real time. It is useful to check the source, destination and type of messages coming in and out of the Operator in an explicit manner.

The monitor is read only. Opening it, filtering it and pausing it change nothing about how MIDI is routed, filtered or merged, so it is safe to leave open while a set is running.

MIDI Monitor can be accessed from the main menu. Scroll to it and Enter it. The monitor opens empty. Messages will start appearing as they arrive or leave the Operator from that point onwards. By default, the monitor watches all five inputs and none of the outputs. The set of watched ports is chosen on the Ports screen, described later in this chapter.

8.1 Reading a line

Every line has the same short format:

>I1 NOn Ch1 C5 v100
>I1 NOf Ch1 C5 v0
>I1 CC  Ch1 #74 v64
>I1 PgC Ch1 #5
>I1 PBn Ch1 +2048

Reading one of those left to right:

  • Direction. Shows > for a message arriving at an input, or < for a message leaving an output.
  • Port. A two-character abbreviation for the port the message was seen on. I1 is Input 1 and O3 is Output 3. USB messages have the letter U rather than a number.
  • Message type. A three-character abbreviation for the message type.
  • Channel. Ch1 to Ch16, printed for channel messages only.
  • Content. What the message actually says, in the form that suits its type.

8.2 Clock and transport

Due to its nature (24 messages per beat), clock message streams do not appear in the monitor. Start, Continue and Stop messages do appear as Srt, Cnt and Stp, so a transport that is running can be confirmed here even though its tempo cannot. The clock settings themselves are covered in Chapter 6 The status bar carries a clock indicator, described in Chapter 4

8.3 Freezing and scrolling

The list holds up to 32 messages. Once it is full, every new message drops the oldest line in the list. Scroll moves through the list.

To stop new messages appearing on the list, perform the Parameters gesture, which freezes the monitor and shows a pause icon on the top right of the screen while it is frozen. The same gesture releases it, making the monitor display new messages again. Independent of the pause, MIDI never stops flowing in or out. The gesture itself is named in Chapter 4

8.4 Monitoring specific ports

Enter, from the monitor, opens the Ports screen. It picks which input and output ports the list shows messages from.

To watch one output and nothing else:

  1. Enter on the monitor to open Ports.
  2. Scroll to the All/None row at the top. Enter it once to check every port, then again to clear them all.
  3. Scroll down to the output to watch and Enter it to check it.
  4. Go Back to the monitor.

8.5 Screen reference

8.5.1 MIDI Monitor

Figure 8.1: MIDI Monitor screen with messages incoming

8.5.2 Port abbreviations

The two characters after the direction marker name the port. Inputs are prefixed with I and outputs with O.

8.5.3 Message types and values

Three characters name the message. Channel messages print a channel and a payload after the abbreviation.

Abbreviation Message Value
NOf Note off Note name and velocity. Note names run from C-1 at note 0 to G9 at 127, so middle C at note 60 reads C4
NOn Note on Note name and velocity. A note on with a velocity of zero is reported as NOf
PAt Polyphonic aftertouch Note name and the pressure on that one note
CC Control change Controller number and its value
PgC Program change Program number
CAt Channel aftertouch Pressure value for the channel
PBn Pitch bend A signed offset from center, +0 at rest and -8192 to +8191 at the extremes
SEx System exclusive F0 and the first two payload bytes, with the rest left off
SPP Song position pointer Nothing
SSl Song select Nothing
TRq Tune request Nothing
Srt Start Nothing
Cnt Continue Nothing
Stp Stop Nothing
ASn Active sensing Nothing
SRs System reset Nothing

Two abbreviations are fallbacks rather than message types. ??? is a channel message whose status the monitor does not recognize, and Sys is a system message that has no abbreviation of its own, such as a MIDI time code quarter frame. Neither should appear on a healthy port, and a stream of either is worth following up on the cable and the sending device.

8.5.4 Ports

Figure 8.2: Monitor's port filter screen

The direction marker in each row is the same > and < the monitor prints in front of every line.