Appendix A: MIDI Implementation Chart
Operator is a MIDI router by design, so what reaches an output is whatever the routing and the filters let through. There is no direct response from the device to any incoming message other than routing it to some destination. Read about routing configuration in Chapter 5
This page describes two specific things: the messages the Operator sends by itself, and the limits of what it can carry at once.
A.1 Messages sent by the Operator itself
| Message | When it is sent |
|---|---|
| Timing Clock | Only while a clock generating mode is loaded and Mode Clock is set to Mode |
| Control Change 120, 64, 123 and 121, all value 0 | MIDI Panic, on all sixteen channels of every physical output, and of Output USB while the device is in Client mode |
| A System Exclusive terminator | To close a message whose route was cut part way through |
| Whatever a loaded mode emits | Under that mode’s own rules, described within each mode in Chapter 10 |
Every message leaves with its own status byte. Running status is resolved on the way in and never used on the way out, which is what makes merging safe: several inputs can feed one output.
A.2 MIDI processing limits
Messages arriving or leaving the Operator are buffered. In everyday operation this is completely unnoticeable, since they are processed at speeds higher than the MIDI protocol allows. Here are the reference numbers of those buffers, in case anyone is curious:
| Limit | Value |
|---|---|
| Messages queued per input | 256 |
| System Exclusive chunks queued per input | 64 |
| Messages queued per output | 512 |
| Messages taken from one input per pass | 32 |
| System Exclusive chunks taken from one input per pass | 8 |
When a buffer is full the newest message is dropped and what is already queued is kept. The per input caps are independent, so one flooded jack cannot take the space the other four need.
A System Exclusive message has no length limit. It travels in 32 byte chunks and is never buffered whole. An output carries one such message at a time, locking it for the duration of its emission or until a full second passes with no further bytes of that message arriving. In the extremely rare case that more than one input is receiving SysEx, any other input’s SysEx message is refused and everything else waits, with System Real-Time the exception that passes through.
One message type does not pass at all. MIDI Time Code quarter frame is parsed, and shows up in the MIDI Monitor, but no message type filter covers it, so it reaches no output. A status byte the MIDI standard leaves undefined is treated the same way.